PROBLEM CAUSE CORRECTION
Projector does not operate No power to projector Plug power cord into suitable electrical outlet. Set power switch to Lamp.
No illumination on screen with slide in projector gate Power switch on Off or Fan Set switch to Lamp.
Lamp burned out Install new lamp or lamp module
Lamp not seated in socket Check lamp.
Slide not in proper focus on screen focus. Slide itself not sharp Examine slide for proper focus.
First slide in tray not properly Focus center of first slide.
Slide in different type of mount from others Focus manually.
Projection lens installed improperly Read and follow the instructions for installing the lens.
Uneven edge-to-edge focus Slide itself is not sharp Examine slide.
Curved field lens used with glass, plastic, or non-embosssed mounts Try a flat field lens. (See Choosing a Curved- or Flat-Field Lens.)
Curved field lens used for rear projection Use a flat field lens.
Autofocus motor runs continuously Glass slides in tray Turn off autofocus or use slides with mounts other than glass.
Autofocus fails to operate Lamp performance Install new lamp and try autofocus again.
Slide fails to drop into projection position Tray base plate not properly indexed Rotate the tray base plate until it locks into position.
Tray not properly positioned on projector Reposition tray on projector.
Slide mount warped or frayed at corners slide. Straighten mount or remount slide.
Projector not level or tilted too high Set projector on a stand equal with center of screen.
Uneven illumination on screen Projection lamp not fully seated Check lamp.
Condenser lens not installed or not positioned properly in mount Check condenser lens.
Slide mount not seated properly in projector gate Check slide position and slide-mount condition.
Projector won't cycle to next slide Tray not properly positioned Reposition tray.
Slide or foreign object stuck in gate See Clearing a Gate Jam.
Program does not start with the with the correct slide Tray number is not aligned with the with the raised index mark. Reposition tray (see Tray).

Previous |  Next

Operating Manual Contents

| Important Safety Instructions | Overview | Introduction & Operation/Startup | Slide Tray | Projecting Your Slides | Editing Your Presentations | Clearing a Gate Jam | Using the Built-In Viewer | Using a Disolve Control | Shutdown | Maintenance | Changing the Projection Lamp | Cleaning the Condenser, Heat-Absorbing Glass, and Mirror | Troubleshooting | Warranty | How to Obtain Service | Special-Application Receptacle Identification Chart