Measuring
Brightness on KODAK Bright White Paper
Brightness Testing
Contents
Effects of equipment
Brightness testing, as it is performed by Kodak, is the reflectance
of blue light (a specific spectral distribution with a principal
wavelength of 457 nm). We make readings in this wavelength because
it coincides with lignin absorption. Lignin is the "glue" that
holds fibers together and can give paper a yellow tint. The brightness
value shows the bleaching quality in in the pulp of the paper.
There are different standard methods of measuring brightness.
The following standard tests are frequently used test methods
in the paper industry.
|
T525
|
Diffuse brightness of pulp (d/0deg)
|
|
T452
|
Brightness of pulp, paper, and paperboard
(directional reflectance at 457 nm)
|
|
ISO 2470
|
Paper and board measurement of diffuse blue
reflectance factor ISO brightness
|
|
ISO 2469
|
Measurement of diffuse factor
|
You can see the differences between brightness tests in the geometry
of the tester: Below, you see two configurations used in brightness
testing.
The Diffuse / 0° Geometry works this way:
-
Two lamps shine in an integrating sphere.
-
The sphere causes light to bounce around and lights the
sample diffusely.
-
A photodetector located perpendicular to the sample plane
records the light coming from the paper surface.
The Directional Brightness Tester has one light that shines at
45[ordm ] to the sample.
When looking at diffuse vs directional brightness, itis important
to know:
Effects of optical brighteners
Since brightness testing is the measure of reflectance of blue
light, brightness measurements are also affected by the presence
of optical brighteners. These brighteners absorb ultra-violet radiation
and emit light in the blue region of the visible spectrum. Therefore,
the amount of ultraviolet radiation that strikes the sample affects
the resulting brightness of the paper. Use of different sources/illuminants
changes the ultraviolet amount as well as the visible spectrum.
Questions and Answers
What method does Kodak use to measure brightness?
Kodak uses a diffuse brightness instrument that conforms to ISO
2469 (Paper, board and pulps measurement of diffuse reflectance
factor). Kodak uses ISO 2469 for test equipment parameters.
The
brightness test is a variation of ISO 2470 (Paper and board-Measurement
of diffuse blue reflectance factor (ISO Brightness).
How does the method Kodak uses to test compare
with competitor's measurements of brightness?
Brightness measurements depend on:
-
Whether you are using a diffuse or directional
brightness tester.
-
The amount of ultraviolet radiation that strikes the sample.
-
The amount of brightners present in the media.
-
The composition of the media.
Why is the role of brighteners important? Why
should we measure it?
Brightners fluoresce with ultraviolet light and emit light at
visible wavelengths. We can see the emitted light with our eyes and
this can influence how we perceive the media.
Kodak is a trademark of Eastman Kodak Company.